30 Mini Split Statistics and US Cost Data (2026)
Compare every state’s electricity cost and 30 findings on mini-split costs, energy use and winter performance.
Source: EIA, Electric Power Monthly 5.6.A, August 2026 and August 2025; released October 23, 2026. The 2026 prices are preliminary; 2025 prices are final.
Key takeaways
- The US residential electricity price averaged 18.16¢/kWh in August 2026. (EIA, October 2026)
- ENERGY STAR certified mini-splits use up to 60% less energy than standard home electric radiators, according to EPA. (EPA ENERGY STAR, accessed October 2026)
- Measured Maine heating COP was 2.57 overall and 1.6 at −10°F to 5°F, including defrost energy. (Efficiency Maine, March 2024)
- ENERGY STAR cold-climate heat pumps must retain at least 70% of their 47°F nominal heating capacity at 5°F. (EPA ENERGY STAR, February 2026)
- BPA’s 2018–19 Northwest evaluation estimated ductless systems replacing zonal heat saved 827–912 kWh/year across heating zones 3 and 2, respectively. (Bonneville Power Administration, July 2021)
- In BPA’s February 2020 survey of Northwest ductless adopters replacing zonal heat, 66% had no prior air conditioning. (Bonneville Power Administration, July 2021)
Mini-split electricity cost data by state
50 states, DC and the reported US average. Equal-energy costs use average residential prices, including bill charges; your tariff can differ.
Opening benchmark: 100 kWh of electricity. Enter metered mini-split energy to compare that amount. Have watts and operating hours? Estimate kWh in the power-use guide, then compare costs here.
52 records · August prices in cents/kWh · cost in USD
| Alabama | 16.33 | 16.26 | +0.43% | $16.33 |
|---|---|---|---|---|
| Alaska | 29.41 | 27.79 | +5.83% | $29.41 |
| Arizona | 15.05 | 15.09 | -0.27% | $15.05 |
| Arkansas | 14.37 | 13.33 | +7.80% | $14.37 |
| California | 29.75 | 30.92 | -3.78% | $29.75 |
| Colorado | 17.17 | 16.21 | +5.92% | $17.17 |
| Connecticut | 24.51 | 30.17 | -18.76% | $24.51 |
| Delaware | 18.70 | 16.85 | +10.98% | $18.70 |
| District of Columbia | 25.98 | 23.18 | +12.08% | $25.98 |
| Florida | 14.99 | 15.33 | -2.22% | $14.99 |
| Georgia | 15.90 | 15.55 | +2.25% | $15.90 |
| Hawaii | 47.18 | 38.53 | +22.45% | $47.18 |
| Idaho | 13.37 | 12.08 | +10.68% | $13.37 |
| Illinois | 19.32 | 18.03 | +7.15% | $19.32 |
| Indiana | 17.02 | 16.21 | +5.00% | $17.02 |
| Iowa | 17.06 | 15.48 | +10.21% | $17.06 |
| Kansas | 15.47 | 14.65 | +5.60% | $15.47 |
| Kentucky | 13.80 | 13.10 | +5.34% | $13.80 |
| Louisiana | 12.87 | 12.55 | +2.55% | $12.87 |
| Maine | 32.11 | 28.14 | +14.11% | $32.11 |
| Maryland | 21.40 | 19.89 | +7.59% | $21.40 |
| Massachusetts | 30.48 | 30.55 | -0.23% | $30.48 |
| Michigan | 22.99 | 20.73 | +10.90% | $22.99 |
| Minnesota | 17.20 | 16.89 | +1.84% | $17.20 |
| Mississippi | 14.43 | 13.61 | +6.02% | $14.43 |
| Missouri | 16.02 | 15.32 | +4.57% | $16.02 |
| Montana | 15.57 | 14.29 | +8.96% | $15.57 |
| Nebraska | 13.54 | 12.80 | +5.78% | $13.54 |
| Nevada | 12.72 | 12.54 | +1.44% | $12.72 |
| New Hampshire | 27.64 | 24.44 | +13.09% | $27.64 |
| New Jersey | 24.61 | 24.70 | -0.36% | $24.61 |
| New Mexico | 16.51 | 15.98 | +3.32% | $16.51 |
| New York | 28.65 | 26.64 | +7.55% | $28.65 |
| North Carolina | 14.95 | 14.59 | +2.47% | $14.95 |
| North Dakota | 13.31 | 12.97 | +2.62% | $13.31 |
| Ohio | 19.38 | 17.55 | +10.43% | $19.38 |
| Oklahoma | 14.82 | 14.42 | +2.77% | $14.82 |
| Oregon | 15.92 | 15.85 | +0.44% | $15.92 |
| Pennsylvania | 21.77 | 19.93 | +9.23% | $21.77 |
| Rhode Island | 28.18 | 26.53 | +6.22% | $28.18 |
| South Carolina | 15.76 | 15.16 | +3.96% | $15.76 |
| South Dakota | 15.15 | 13.90 | +8.99% | $15.15 |
| Tennessee | 13.42 | 13.09 | +2.52% | $13.42 |
| Texas | 15.91 | 15.40 | +3.31% | $15.91 |
| US averageReported national aggregate | 18.16 | 17.57 | +3.36% | $18.16 |
| Utah | 13.31 | 13.62 | -2.28% | $13.31 |
| Vermont | 23.84 | 22.10 | +7.87% | $23.84 |
| Virginia | 17.64 | 15.85 | +11.29% | $17.64 |
| Washington | 14.63 | 13.65 | +7.18% | $14.63 |
| West Virginia | 16.31 | 15.62 | +4.42% | $16.31 |
| Wisconsin | 19.41 | 18.44 | +5.26% | $19.41 |
| Wyoming | 14.43 | 14.33 | +0.70% | $14.43 |
No states match that search. Try the full state name or reset the table.
What do US mini-split energy and ownership costs look like?
Keep an electricity price, an installed quote and a modelling assumption separate.
| Reference | What it covers |
|---|---|
| August 2026 electricity | Residential state averages, preliminary |
| Carrier installed range | Single- and multi-zone projects; no local average |
| 2023 equipment model | Assumed life and maintenance, in 2022 dollars |
- The US residential electricity price averaged 18.16¢/kWh in August 2026. (EIA, October 2026)
- State residential electricity prices ranged from 12.72¢/kWh in Nevada to 47.18¢/kWh in Hawaii in August 2026. (EIA, October 2026)
- Carrier gives a US installed ductless mini-split planning range of $2,500 to $15,000 or more, varying with zones and installation complexity. (Carrier, accessed October 2026)
- The March 2023 EIA equipment model assumes a 15.3-year average life for residential ductless mini-splits, rather than measuring their service life. (Guidehouse and Leidos for EIA, March 2023)
- The March 2023 EIA equipment model assumes $100 a year in maintenance, in 2022 dollars, for residential ductless mini-splits. (Guidehouse and Leidos for EIA, March 2023)
How much electricity can a mini-split save or use?
Savings depend on the equipment replaced and the heat actually delivered.
| Comparison | Scope |
|---|---|
| ENERGY STAR savings | Certified mini-split versus electric radiator |
| DOE savings | Air-source heat pump versus electric resistance |
| Maine electricity use | Evaluated supplemental systems; weather-normalized |
- ENERGY STAR certified mini-splits use up to 60% less energy than standard home electric radiators, according to EPA. (EPA ENERGY STAR, accessed October 2026)
- EPA estimates whole-house ENERGY STAR mini-splits avoid on average more than 4,500 lb of greenhouse-gas emissions over their lifespan versus standard systems. (EPA ENERGY STAR, accessed October 2026)
- DOE states modern air-source heat pumps can reduce electricity use by 50% compared with electric furnaces and baseboard heaters. (US Department of Energy, May 2023)
- Normalized annual electricity averaged 1,887 kWh for heating and 252 kWh for cooling per evaluated heat pump in Maine. (Efficiency Maine, March 2024)
What did Maine measure in real homes?
The evaluation mainly covered supplemental heat pumps, with prior heating retained; these are not whole-home national averages.
| Measure | Study basis |
|---|---|
| Metering | 2021–2023; Maine |
| Heating efficiency | Includes defrost |
| Demand peak | 119 outdoor units |
| Annual heating output | 140 evaluated heat pumps |
- The Maine study metered 124 homes across all 16 counties, mainly with supplemental systems. (Efficiency Maine, March 2024)
- Measured Maine heating COP was 2.57 overall and 1.6 at −10°F to 5°F, including defrost energy. (Efficiency Maine, March 2024)
- Evaluated Maine heat pumps delivered a mean 16.6 MMBtu of heat per year. (Efficiency Maine, March 2024)
- Maine participants’ heating/cooling comfort ratings ranged from 4.3 to 4.7 out of 5 across program/mode groups. (Efficiency Maine, March 2024)
- Maine’s evaluated heat pumps saved 2,988 kWh/year against the study’s electric-heating baseline. (Efficiency Maine, March 2024)
- Mean metered demand peaked at 0.8 kW per outdoor unit at 2°F in Maine’s 119-unit demand sample. (Efficiency Maine, March 2024)
What do mini-split efficiency and cold-climate labels require?
A seasonal efficiency rating and a cold-weather capacity test answer different questions.
| Requirement | Published threshold |
|---|---|
| ENERGY STAR split system | SEER2 ≥15.2; HSPF2 ≥7.8; EER2 ≥11.0 |
| ENERGY STAR cold, non-ducted | SEER2 ≥15.2; HSPF2 ≥8.5 |
| Cold-weather efficiency | COP ≥1.75 at 5°F |
| Cold-weather capacity | At least 70% of the 47°F nominal output at 5°F |
- EPA’s US split-system heat-pump criteria require 15.2 SEER2 and 7.8 HSPF2, rising to 8.5 HSPF2 for cold-climate non-ducted systems. (EPA ENERGY STAR, February 2026)
- ENERGY STAR cold-climate heat pumps must achieve a COP of at least 1.75 at 5°F under the specified low-ambient test. (EPA ENERGY STAR, February 2026)
- ENERGY STAR cold-climate heat pumps must retain at least 70% of their 47°F nominal heating capacity at 5°F. (EPA ENERGY STAR, February 2026)
- NEEP’s 2023 residential cold-climate specification requires at least 3 distinct compressor speeds or continuously variable capacity. (NEEP, January 2023)
- NEEP’s residential performance tables request heating data at 47°F, 17°F and 5°F, excluding defrost and drain-pan-heater power. (NEEP, January 2023)
When can cold-climate heating costs favor a hybrid system?
The ACEEE study models US existing homes and 2030 replacements; these are scenario results.
| ACEEE model result | Scope |
|---|---|
| Around 7,000 heating degree days or more | Heat pumps with biofuel backup versus reduced-carbon-fuel alternatives |
- ACEEE’s 2024 US existing-home study models 2030 replacements and finds heat pumps with biofuel backup minimize life-cycle costs versus reduced-carbon-fuel alternatives around 7,000 heating degree days or more. (ACEEE, April 2024)
How much backup fuel did the hybrid-heating study require?
The tank result applies to modelled hybrid heating, rather than an all-electric mini-split.
| ACEEE hybrid-heating result | Scope |
|---|---|
| 100-gallon tank, filled annually | Meets winter backup needs for a substantial majority of modelled homes |
- ACEEE’s 2024 US hybrid-heating analysis finds a 100-gallon backup-fuel tank, filled annually, meets winter backup needs for a substantial majority of its modelled homes. (ACEEE, April 2024)
What have other cold-climate heat-pump field studies found?
These studies include ducted systems; their results retain their own systems, climates and measurement boundaries.
| Field result | Measurement boundary |
|---|---|
| 1.9 median heating COP | 0–5°F; heat-pump-only periods |
| 25% auxiliary use | −10–0°F; defrost excluded |
| 3.4–5.2 median cooling COP | Temperature-bin medians; unusually cool cooling bins excluded |
| 30–56% cost savings | CEE: seven Minnesota sites, ducted and ductless systems |
- PNNL’s 22-unit US/Canada ducted-prototype study found a median heating COP of 1.9 at 0–5°F, excluding auxiliary heat and defrost. (PNNL, January 2025)
- PNNL’s ducted-prototype field study observed auxiliary heat operating for 25% of heating time at −10–0°F, excluding defrost. (PNNL, January 2025)
- PNNL’s ducted-prototype study reported temperature-bin median cooling COPs of 3.4 to 5.2, excluding unusually cool cooling-operation bins. (PNNL, January 2025)
- A seven-site Minnesota study of ducted and ductless cold-climate heat pumps reported 30–56% cost savings in its September 2018 results. (Center for Energy and Environment, September 2018)
Why can a more efficient mini-split deliver smaller bill savings?
Adding cooling or conditioning more rooms changes the service a household receives.
| BPA 2018–19 evaluation | Result / population |
|---|---|
| Ductless replacing electric zonal heat | 912 kWh/year saved in zone 2; 827 in zone 3 |
| Prior air conditioning | 66% of surveyed adopters had none |
| Comfort as a purchase reason | 73% rated it very or extremely important |
| Survey size | 131 replies; 73% response rate |
- In BPA’s February 2020 survey of Northwest ductless adopters replacing zonal heat, 66% had no prior air conditioning. (Bonneville Power Administration, July 2021)
- In BPA’s February 2020 ductless-adopter survey, 73% rated comfort very or extremely important to their purchase. (Bonneville Power Administration, July 2021)
- BPA’s 2018–19 Northwest evaluation estimated ductless systems replacing zonal heat saved 827–912 kWh/year across heating zones 3 and 2, respectively. (Bonneville Power Administration, July 2021)
- BPA’s February 2020 Northwest ductless-adopter survey received 131 responses, a 73% response rate. (Bonneville Power Administration, July 2021)
Methods and refresh
We checked 46 candidate figures and kept 30 findings from primary sources, retaining each study’s scope and dates; next review: January 24, 2027. Suggest a correction.
Cite this page
Mini Split BTU Calculator. “30 Mini Split Statistics and US Cost Data (2026).” Updated October 24, 2026. https://minisplitbtucalculator.com/mini-split-install-price/mini-split-statistics/
Primary sources
- EIA: Electric Power Monthly, Table 5.6.A (October 2026).
- Guidehouse and Leidos for EIA: Equipment costs and efficiencies, Appendix B, p. 44 (March 2023).
- Carrier: US ductless mini-split installation cost guide (accessed October 2026).
- EPA ENERGY STAR: Ductless heating and cooling (accessed October 2026).
- EPA ENERGY STAR: Heat pump eligibility criteria, Version 6.2, revised February 2026 (February 2026).
- US Department of Energy: Pump up your savings with heat pumps (May 2023).
- Efficiency Maine: Residential heat pump impact evaluation, pp. 9–14, 51–63 (March 2024).
- NEEP: Cold climate ASHP specification v4, effective January 2023 (January 2023).
- ACEEE: Options for decarbonizing residential space heating in cold climates (April 2024).
- PNNL: Cold climate heat pump challenge field validation, executive summary (January 2025).
- Bonneville Power Administration: 2018–19 residential HVAC impact evaluation, pp. 1–3, 23–24, 34 (July 2021).
- Center for Energy and Environment: Field assessment of ducted and ductless cold climate air source heat pumps (September 2018).